Quick answer: A 3D scanner portable shockproof hard safety case with a 13 mm rim and four 16 mm posts holds squareness at 0.3 mm after a 30 g / 11 ms shock.
Table of contents
- Sealing rim width of the 3D scanner portable shockproof hard safety case
- Height allocation of the inner locating posts
- Perpendicularity readings by shock direction
- Post position retention after the drop retest
- Rim width rejection line for hard-shell batches
- FAQ
1. Sealing rim width of the 3D scanner portable shockproof hard safety case
The 3D scanner portable shockproof hard safety case keeps a 13 mm sealing rim around the mouth, a ledge that seats the gasket and resists sideways lid shift. The 4.1 mm shell wall flares into a platform anchoring the 8 mm post roots. Between a 520 x 380 x 205 mm envelope and a 455 x 320 x 150 mm cavity, the remaining wall is shared between the flange and the post seats; a rim cut too narrow lets the lid slide under shock.
Rim width of the 3D scanner portable shockproof hard safety case is sampled at six points around the perimeter, each held within 0.2 mm of the 13 mm nominal. JUNZHIJIA checks rim width together with post height as one pair, since the rim governs sideways restraint and the posts govern vertical support, and both take the 30 g / 11 ms half-sine shock. Neither figure alone predicts post perpendicularity afterwards.
| Rim tier | Measured rim | Post squareness after 30 g / 11 ms |
|---|---|---|
| Narrow | 11 mm | 0.38 mm, reject |
| Nominal | 13 mm | 0.24 mm |
| Wide | 15 mm | 0.19 mm |
2. Height allocation of the inner locating posts
Four locating posts, each 16 mm high and 8 mm across, sit at the corners of the 455 x 320 x 150 mm cavity of the 3D scanner portable shockproof hard safety case. Taller posts act as cantilevers under shock; shorter ones leave a gap at the lid frame. At 9.5 kg loaded, 16 mm lets each post top meet the inner frame, so shock runs down the post into the base rather than loading the rim alone.
Post-to-seat interference of the 3D scanner portable shockproof hard safety case is held near 0.1 mm, since a loose root turns on the shock rig and the perpendicularity reading includes assembly play. The shell runs 4700 empty open-close cycles first, then goes onto the 30 g / 11 ms half-sine table. Two latches at 355 N each are checked here; any run with the lid not fully pressed is excluded.
3. Perpendicularity readings by shock direction
The half-sine shock of the 3D scanner portable shockproof hard safety case is set at 30 g / 11 ms along the long side, the short side and the vertical axis, with post perpendicularity measured against the base datum after each run. The ceiling is 0.3 mm, and the long side works hardest because inertia pushes all four posts toward one flank. Both 4.7 kg empty and 9.5 kg loaded states are run, and the larger squareness value is recorded.
| Shock direction | Squareness at 30 g / 11 ms | Reading |
|---|---|---|
| Long side | 0.26 mm | governing direction |
| Short side | 0.18 mm | secondary direction |
| Vertical | 0.21 mm | check direction |
The clamp itself drifts about 0.02 mm at zero after repeated shocks, so a separate card column removes that play. Three corrected curves placed together show which run truly bent a post and which only loosened the tooling; a sound batch is not rejected on the fixture's account.
4. Post position retention after the drop retest
After the shock programme the 3D scanner portable shockproof hard safety case goes through a 1.2 m six-face drop, landing on the diagonal opposite the posts. The post roots are checked by eye for blushing, then squareness is remeasured; the gap from the shock terminal value must stay within 0.06 mm. A 1.2 m drop and a 30 g / 11 ms half-sine shock are two loads, one probing joint loosening and the other post bending.
The drop retest of the 3D scanner portable shockproof hard safety case also checks whether the 13 mm rim has been crushed, since a dented platform weakens sideways restraint. An IP65 spray retest follows, where the single gasket at 22 percent compression still has to seal and the mouth must not warp from rim deformation.
5. Rim width rejection line for hard-shell batches
For the 3D scanner portable shockproof hard safety case, eight shells per batch are measured at the rim, and a reading 1.5 mm under the 13 mm nominal is a reject; two such shells send the whole batch back. The line matches the narrowest rim that still holds squareness within 0.3 mm after a 30 g / 11 ms shock. JUNZHIJIA writes it into the process card and reruns one full 30 g / 11 ms check after any tool or material change.
Rejection records for the 3D scanner portable shockproof hard safety case map one to one onto squareness values and are filed by shell number.
| Squareness value | Matching rim tier | Disposition |
|---|---|---|
| no more than 0.3 mm | nominal 13 mm | release |
| 0.3 to 0.4 mm | narrow 11 mm | remeasure posts |
| above 0.4 mm | reject band | whole batch rework |
Conclusion
The 3D scanner portable shockproof hard safety case pairs a 13 mm sealing rim with four 16 mm posts to hold post squareness within 0.3 mm after a 30 g / 11 ms half-sine shock, with the 1.2 m drop retest covering joint loosening. JUNZHIJIA files the measured rim, the direction curves and the rejection line, and reruns them after any tool change. When specifying a hard-shell case of this kind, ask first whether rim width and post height come with measured figures.
Related Reading
- 3D printed part protective case selection
- Metrology box series specifications
- Metrology standard case structure
- Laser distance meter pre-cut foam protective box
Related Products
- 8 Series — Gun Cases; Military Equipment Cases; Camera Equipment Cases; Drone Cases; Watch Cases; Knife Cases; First Aid Cases; Electronics Equipment Cases
- WL8-2812 PP Gun Case — model WL8-2812
- All protective cases and toolboxes: 7 series, 158 models