Quick answer: Medical endoscope cleaning & transit box divider tilt rests on slot depth 8.5 mm and lid rib pitch 145 mm, holding the tilt angle above 72 degrees.
Table of contents
- Slot depth in the Medical endoscope cleaning & transit box
- Pitch of the lid hold-down ribs
- Tilt readings by transfer sequence
- Slot-mouth wear after repeated insertion
- Slot-depth convergence across transfer batches
- FAQ
1. Slot depth in the Medical endoscope cleaning & transit box
A divider does not tip because it bends; when slot depth and rib pitch fall out of step, each transfer amplifies the small sway a little more. A removable divider sits in slots cut into the inner shell wall. Slot depth decides how much root is gripped and how much sway is absorbed. Outer dimensions of 660×450×250 mm, an inner cavity of 590×385×180 mm and a 4.8 mm wall leave fixed room for the slots. Beyond a limit, either the root floats or clear inner height is lost. The Medical endoscope cleaning & transit box cuts its slots into the side walls rather than the floor, so the root has a full straight wall to lean against.
The baseline slot depth of 8.5 mm was set on a bench held at 23 ℃ / 50% RH. Root sway was measured at an empty 8.0 kg and a loaded 19 kg: below the baseline the loaded sway is larger, while at 8.5 mm the two converge, which says the slot has taken hold. This step of the Medical endoscope cleaning & transit box concerns only the fit between slot and divider, and says nothing about what sits inside the case.
| Slot depth grade | Loaded behaviour | Effect on cavity height |
|---|---|---|
| Below baseline | Small sway accumulates | Least height used |
| Baseline 8.5 mm | Sway absorbed by slot | Matches 180 mm cavity |
| Above baseline | Sway held but insertion stiff | Squeezes cavity height |
Pushing slot depth further stiffens insertion and sheds debris at the slot mouth; the usable band has its lower edge at 8.5 mm.
2. Pitch of the lid hold-down ribs
The slot governs only the divider root; the top edge still needs the lid hold-down ribs. A pitch of 145 mm in the Medical endoscope cleaning & transit box is the centre-to-centre distance between two ribs on the inner lid face; too wide a pitch leaves the stretch of divider between ribs without upper constraint, so it pitches forward around the slot root when the case is moved.
Slot and rib are an upper-and-lower pair, so the pitch is read with slot depth. An 8.5 mm slot with a 145 mm pitch holds the divider from root to top; deepen the slot without tightening the pitch and the top still sways. Four latches rated at 435 N pass closing force into the ribs, two seal rings at 22% compression stop lid spring-back, and the rim is checked against water spray by the IP66 method.
Rib pitch is lid-side and slot depth base-side; the transfer reading is the outcome of the pair.
3. Tilt readings by transfer sequence
The transfer sequence runs to 20 cycles with the tilt angle measured after each one, the criterion being an angle still at or above 72° at the 20th cycle. The bench for the Medical endoscope cleaning & transit box joins the 20 readings into one curve, which says more about progressive loosening than any single last reading, and a 19 kg load runs throughout.
| Transfer sequence | Tilt reading | Verdict |
|---|---|---|
| First cycle | Clearly above 72° | Pass |
| Mid run | Near the threshold | Track |
| 20th cycle | Holds 72° | Converged |
The tilt angle falls as the slot root loosens a fraction at a time; a steeper late slope means the upper rib slackens first and the slot is then levered. Lid durability of 4300 open-close cycles and the 20 transfers are logged separately against their own thresholds.
4. Slot-mouth wear after repeated insertion
The divider is removable, so repeated insertion leaves a polished trace at the slot mouth. The Medical endoscope cleaning & transit box caps slot-mouth wear at 0.2 mm / 1000 cycles, the growth in slot width after 1000 insertions rather than a loss in the divider itself, and the reading sits on the shell slot.
Once wear reaches a certain point the slot grips the root less firmly and the tilt angle falls faster at the same sequence, so insertion recheck sits beside transfer recheck. The Medical endoscope cleaning & transit box keeps both numbers on a single row at 23 ℃ / 50% RH and 19 kg, alternating 1000 insertions against 20 transfers.
5. Slot-depth convergence across transfer batches
Put slot depth and tilt reading from three batches side by side, change only slot depth per batch, lock the rib pitch at 145 mm and hold a 19 kg load, and the difference is attributed cleanly to slot depth, which is why the Medical endoscope cleaning & transit box files results by batch.
| Tilt reading | Converged | Action |
|---|---|---|
| Clearly below 72° | No | Whole batch back to retool |
| Holds 72° twice running | Yes | Write into drawing |
| Holds but insertion stiff | No | Trend record only |
The convergence value is the shallowest grade whose tilt angle holds 72° on two consecutive rechecks; deeper slots are not allowed to take up clear cavity height.
The value settles at 8.5 mm and the matching 145 mm pitch goes onto the drawing with it. Batch release reads 20 transfers, slot-mouth wear at or below 0.2 mm / 1000 cycles and 4300 open-close cycles together; a crossed line sends the cause back to the slot-and-rib pairing. The Medical endoscope cleaning & transit box freezes this criterion, and JUNZHIJIA has the batch moulded to drawing by Kexin New Materials (Guangdong) Co., Ltd., with bench readings kept per shell batch.
Conclusion
The divider stability of the Medical endoscope cleaning & transit box comes down in the end to how slot depth pairs with rib pitch. An 8.5 mm slot, a 145 mm pitch, a tilt angle at or above 72° after 20 transfers and slot-mouth wear at or below 0.2 mm / 1000 cycles turn divider-location ability into repeatable readings. Compare the three tables of slot grade, transfer sequence and tilt reading to see whether every batch lands on the same convergence value.
Related Reading
- Medical ECG monitor transport latch case
- Medical-grade waterproof shockproof transport case
- Medical equipment plastic case in-hospital transit configuration
- Medical device transport case: protection, compliance and clean handling