Quick answer: Acceptance of an ESD plastic box rests on five measurable items — surface, volume resistance, static decay, triboelectric voltage and grounding loop resistance — plus batch consistency. Each needs an instrument, a condition and a pass value; with all three written down, two laboratories reach the same verdict.
Table of contents
- ESD plastic box standards: the order of acceptance
- Reading surface and volume resistance
- Decay time and triboelectric voltage
- Grounding and loop resistance
- Batch consistency, marking and sampling
- FAQ
1. ESD plastic box standards: the order of acceptance
Fix the items first, the instruments second, the pass values last. Reversed, the plan becomes whatever the lab owns. Conditions matter as much as accuracy: resistance runs at 23 °C ± 3 °C, at 50 and 12 percent humidity, because the same box reads two orders higher in dry air.
| Item | Instrument | Pass value |
|---|---|---|
| Surface resistance | High-resistance meter, 2.27 kg electrode | 1×10⁴ to 1×10¹¹ ohm at 100 V |
| Volume resistance | Plate electrodes, read at 60 s | Not above 1×10¹¹ ohm·cm |
| Static decay | Field meter with discharge plate | 1000 V to 100 V within 2.0 s |
| Triboelectric | Nylon cloth, 500 g, 10 passes | Peak not above 100 V |
| Grounding loop | Loop tester at 1 A | Not above 1 ohm |
Sample five ESD plastic box units per lot, five points each; one point outside fails the unit.
2. Reading surface and volume resistance
Surface resistance is the most misread number on an ESD plastic box. Three bands work better than one, and the voltage must be stated: 100 V and 500 V differ by half an order.
Volume resistance describes the compound, not the skin. With carbon black unevenly dispersed, surface passes while volume drifts past 1×10¹² ohm·cm, pointing to a coating or an additive that wipes off.
| Class | Surface | Volume | Verdict |
|---|---|---|---|
| Conductive | Below 1×10⁴ ohm | Below 1×10⁴ ohm·cm | Permitted in explosive areas |
| Dissipative | 1×10⁴ to 1×10¹¹ ohm | Not above 1×10¹¹ ohm·cm | Standard for electronics assembly |
| Insulating | Above 1×10¹¹ ohm | Above 1×10¹² ohm·cm | Barred from sensitive areas |
3. Decay time and triboelectric voltage
Passing resistance does not mean fast discharge. Decay runs from 1000 V to 100 V, and the 2.0 s limit applies at 12 percent RH, where dry air leaves no water film and charge must travel through the compound itself.
Triboelectric voltage sits closer to the floor. A nylon cloth around a 500 g load makes ten passes while a field meter reads the peak at 25 mm; above 100 V fails. The same ESD plastic box peaks at 40 V humid and 300 V dry, so a record without humidity compares with nothing.
| Item | Condition | Limit and usual cause |
|---|---|---|
| Decay time | 1000 V to 100 V, 12 percent RH | 2.0 s; additive migration |
| Triboelectric | 500 g nylon, 10 passes | 100 V peak; local insulation |
| Decay repeat | Same box, five cycles | 0.3 s spread; surface residue |
4. Grounding and loop resistance
A dissipative ESD plastic box works without a terminal, but once one is fitted the loop must be measurable: conductor not below 0.5 mm², 1 ohm at 1 A. An oxidised crimp doubles that inside three months.
With no terminal, keep surface resistance between 1×10⁶ and 1×10⁹ ohm so charge bleeds away slowly, and avoid an isolated conductor that dumps everything at once. Most lines stand it on a dissipative mat and read contact resistance, at a limit of 1×10⁹ ohm.
5. Batch consistency, marking and sampling
Batch consistency is the item most often skipped. Inside one lot the spread should stay within one decade; above 20 percent regrind the filler network dilutes and every reading shifts up. After 1000 hours of ageing, drift should stay within half a decade.
Marking has to reach the cavity: batch number, cavity number, date and material grade, by laser or in-mould label, surviving 50 alcohol wipes. The cavity number decides what goes to quarantine.
| Lot size | Sample | AQL |
|---|---|---|
| 151 to 280 | 20 | 1.0 resistance, 2.5 appearance |
| 281 to 500 | 32 | 1.0 resistance, 2.5 appearance |
| 501 to 1200 | 50 | 1.0 resistance, 2.5 appearance |
Conclusion
Acceptance turns six items into repeatable steps: resistance at a fixed voltage, decay at a fixed humidity, triboelectric voltage at a fixed load, grounding at a fixed current. Loose conditions make the numbers meaningless; fixed ones let an ESD plastic box pass without one inspector's memory.
This article covers container-side specifications and design implications only, not the handling, loading or use of the contents.
Related Reading
- Three verdicts in military supply case inspection
- Control points for appearance and assembly quality
- Protection classes and acceptance for waterproof hard cases
- Material comparison for portable plastic tool boxes
Related Products
- 8 Series — Gun Cases; Military Equipment Cases; Camera Equipment Cases; Drone Cases; Watch Cases; Knife Cases; First Aid Cases; Electronics Equipment Cases
- WL8-2812 PP Gun Case — model WL8-2812
- All protective cases and toolboxes: 7 series, 158 models