Quick answer: An Industrial Controller Protective Case pairs an 8 mm gasket holding 40 dB with 24 vent holes of 3 mm keeping a 35 W rise to 12 K.

Table of contents

  • Shielding gasket of an Industrial Controller Protective Case
  • Vent holes and dust ingress
  • Temperature rise at thirty-five watts
  • Discharge path for eight kilovolts
  • Shielding setting for a controller batch
  • FAQ

1. Shielding gasket of an Industrial Controller Protective Case

The gasket of an Industrial Controller Protective Case runs the lid perimeter at 8 mm, closing to 6.4 mm, a 20% compression. The shell is 480 by 380 by 200 mm outside and 420 by 320 by 150 mm inside behind a 4.0 mm wall, and its 380 mm long edge leaks first: a probe swept along it loses reading fastest between 30 MHz and 200 MHz. A thinner gasket leaves a taller gap; a thicker one loads four latches harder, and after 6000 closings the gasket root crushes first.

Three grades of the Industrial Controller Protective Case take ten shells each on one bench and one probe, sampled every 60 mm, with only the lowest loop reading entered. The reject line sits at 6 dB of margin, so a grade reading 34 dB goes back to the mould.

Gasket gradeSection thicknessLid compressionShielding reading
One thinner6 mm15%34 dB
Nominal8 mm20%40 dB
One thicker10 mm26%41 dB

The thin grade touches the line at 34 dB, nominal holds 40 dB, and the thick grade gains one decibel to 41 dB while compression climbs to 26% and a latch must close at 320 N. That decibel never pays for latch life, so nominal stays in the setting sheet.

2. Vent holes and dust ingress

Inside an Industrial Controller Protective Case a controller hands 35 W to the wall and the wall to the outside air, leaving the vents as the only adjustable link. Twenty-four holes of 3 mm across the side total 170 mm², or 0.22% of the 380 by 200 mm face. A wider ratio lowers the rise and lets dust ride the same airstream in, so both lines must close at one grade.

Industrial Controller Protective Case in light grey, open inside a van body, adjustable dividers, strapped cartons at right
Industrial Controller Protective Case in light grey, open inside a van body, adjustable dividers, strapped cartons at right

An Industrial Controller Protective Case adds holes rather than widening them. A 4 mm bore reaches the same area with 14 holes but grows each frontal area 78%; 24 to 32 holes keeps the bore and evens the airflow.

Vent layoutCount and boreOpen ratioRise
Sparse16 × 3 mm0.15%15 K
Nominal24 × 3 mm0.22%12 K
Dense32 × 3 mm0.30%10 K

At 0.22% the rise is 12 K; at 0.30% it falls to 10 K, so 56 mm² of extra intake buys 2 K. An Industrial Controller Protective Case judges on dust: above 0.30% a shell shows visible dust inside after 8 h on the dust bench and the batch is refused.

3. Temperature rise at thirty-five watts

Thirty-five watts inside an Industrial Controller Protective Case, spread over 0.71 m², gives roughly 49 W/m² at the outer surface, and steady state arrives after 90 min. At 25 ℃ ambient three probes average a 12 K rise, putting the cavity at 37 ℃, still 18 K under the 55 ℃ limit common to industrial controllers.

The probes sit at centre 60 mm above the base, 25 mm from the panel wall and 40 mm from the vent wall. The hottest runs 3 K above the average, so the sheet records the average and lists the spread separately.

The slope is not flat: each 0.01% of ratio buys 0.4 K between 0.15% and 0.22%, but only 0.25 K above that. Parked in a 45 ℃ van the cavity margin narrows under 10 K while the shell still reads 12 K, because the starting point moved.

4. Discharge path for eight kilovolts

Eight kilovolts entering a panel seam must reach ground inside the shell, and a shorter path with tighter bonds leaves a lower residual. Four points carry it: one at each lid side through the gasket into the wall, and two panel studs landing on ground posts in the base.

Industrial Controller Protective Case parts box in clear plastic, open on an outdoor bench, coloured crimp terminals, screws and wire inside
Industrial Controller Protective Case parts box in clear plastic, open on an outdoor bench, coloured crimp terminals, screws and wire inside

The path is measured in segments, 210 mm through the lid gasket and 160 mm through the studs, with each extra overlap adding a contact drop. After an 8 kV injection the lid route holds 1.4 kV and the stud route 0.9 kV; the 0.5 kV between them is the price of overlaps.

Discharge linkGround pointsPath lengthResidual after 8 kV
Lid gasket to wall2 points210 mm1.4 kV
Panel stud to base2 points160 mm0.9 kV
Combined4 points370 mm0.9 kV

Drop one point and the other route carries the whole discharge, lifting residual past 2 kV, with the shielding reading able to fall 2 dB alongside. An Industrial Controller Protective Case checks ground points shell by shell, and a shell missing one earns no grade. Paint between gasket and wall breaks that path, so assembly keeps a bare patch at each overlap.

5. Shielding setting for a controller batch

An Industrial Controller Protective Case closes a batch on two lines: the lowest lid reading holds 40 dB and the rise stays at 12 K or under. The smallest gasket thickness and open ratio inside both lines become the setting.

The setting travels with the shell: an 8 mm gasket, a 0.22% ratio, four ground points and 6000 closings lock into the batch boundary. A new gasket compound or a shift of hole position restarts both benches.

Counting is per shell, one sheet each: thickness, lowest reading, ratio, rise, ground points and residual. Six entries in one grade make the shell graded; one missing entry pulls it alone.

Conclusion

Grading an Industrial Controller Protective Case holds two lines at once: an 8 mm gasket keeps the lowest reading at 40 dB, and 24 holes of 3 mm hold a 35 W rise to 12 K with 6 dB of margin. A thinner or thicker gasket sends the batch back, since one spare decibel never pays for latch life. JUNZHIJIA files 6000-closing retest records by batch, and drawing tolerances are issued by Kexin New Materials (Guangdong) Co., Ltd.