Quick answer: Injection floor layout rests on four numbers: press centres 4.5 m apart, cable tray at 3.8 m, WIP aisle 2.2 m, mold area 6×8 m.

Table of contents

  • Machine pitch on the molding floor
  • Pipe routing and tray height
  • Width and direction of the WIP aisle
  • Where the mold area sits relative to the presses
  • Floor marking and safety clearance
  • FAQ

1. Machine pitch on the molding floor

Half a metre short on pitch, and the mold cart and the parts cart meet head-on at the aisle mouth. Injection floor layout measures centre to centre, and 4.5 m is the common figure for presses of 100 to 250 t: 1.6 m for the machine, 0.8 m on the operator side, 0.6 m at the back, and 1.5 m of aisle between two rows. Squeeze one and the other three move with it.

As tonnage climbs the pitch opens up. A press above 250 t measures 2.2 m across and carries larger platens, so centres go to 5.5 m for a robot arm and for lifting; below 100 t, 3.5 m works if a 1.5 m service gap sits nearby, because someone has to stand there when the screw is pulled.

Clamp forceMachine widthSuggested pitchOperator clearance
under 100 t1.3 m3.5 m0.7 m
100–250 t1.6 m4.5 m0.8 m
above 250 t2.2 m5.5 m1.0 m

Pitch then has to be checked against how the case travels. A case leaves the mold onto a take-off table, and a person carries it to the parts cart; once that walk passes 1.2 m, each cycle gains 4 s. Injection floor layout keeps the table out of the aisle, and shifts a row 0.3 m when a column stands proud rather than narrowing the operator side.

2. Pipe routing and tray height

A tray at 3.8 m is the compromise between walking below and reaching above. Injection floor layout stacks services in three bands: cooling water and air at 2.6 m, cable tray at 3.2 m, exhaust duct at 3.8 m, with 300 mm between them so a hand can reach a coupling. The tray runs 300 mm above the pipe, crossings use a 1 m bridge, and no water joint sits over a panel, because every clamp stroke shakes the pipework.

ServiceHeightGap to neighbourFixing
Cooling water2.6 m300 mm to cableclamp every 2 m
Compressed air2.8 m300 mm to cableclamp every 2 m
Cable tray3.2 m300 mm to waterbracket every 1.5 m
Exhaust duct3.8 m300 mm to trayhanger every 3 m

Tray height decides the service method too. At 3.8 m nobody reaches from the floor, so a 2 m mobile platform is needed; with 6 m clear height it stands with 0.2 m to spare, while a 5 m hall forces the exhaust onto a side wall. Injection floor layout books that 0.2 m early, since rerouting a duct later rebuilds a run. Run cooling mains at 1% to the return end with a drain at the low point.

3. Width and direction of the WIP aisle

A 2.2 m work-in-progress aisle comes from a 1.2×1.0 m pallet plus 0.5 m each side: the pallet takes 1.2 m across the aisle and the strips cover passing and door swing. Turned the narrow way it takes 1.0 m, but the arc at a corner grows, so injection floor layout sets the line for the wide orientation. Two-way flow would need 3.2 m for two 1.6 m lanes, so most halls run a one-way loop.

Injection Floor Layout assembly stations where three women fit parts, grey-green cases stacked eight high, blue bins of black components.
Injection Floor Layout assembly stations where three women fit parts, grey-green cases stacked eight high, blue bins of black components.

Injection floor layout keeps the aisle mouth clear once the direction is fixed. Both sides carry a 0.5 m yellow no-store strip, and case stacks wait in bays, one per bay and no higher than 1.8 m. A stack at the edge turns 2.2 m into 1.4 m, and two carts then back out, at least 40 s each time. A 2.5×2.5 m turning square keeps carts from reversing into a work cell.

4. Where the mold area sits relative to the presses

A 6×8 m mold area inside the reach of a 5 t crane, with two change positions, is the working target. Injection floor layout does not put it at the end of the WIP aisle: that corner looks empty but is the throat of the flow. Set it alongside the press row, joined by a 1.5 m spur that every mold movement uses.

Injection Floor Layout work-in-progress aisle with kraft-brown cases stacked more than ten high and wrapped, presses and green floor lines behind.
Injection Floor Layout work-in-progress aisle with kraft-brown cases stacked more than ten high and wrapped, presses and green floor lines behind.

Keep the area within 15 m of the farthest press: a 5 t crane covers 15 m in 45 s, and a change runs about 20 min of support time, doubling at 30 m. The floor needs its own slab, since three tiers of racking push the local load past 3 t/m², so injection floor layout calls for 200 mm of reinforced concrete. Two change positions take turns, 1.2 m apart, so both hooks work at once.

5. Floor marking and safety clearance

Floor lines in an injection floor layout are 100 mm wide, yellow solid for aisle edges and green dashed for walkways. At 3 m, 100 mm reads clearly, 50 mm blurs from a forklift seat, and 150 mm eats into the aisle. Safety clearance is 1.0 m from any moving press part, covering 0.4 m of platen travel, 0.3 m of robot swing and 0.3 m of retreat space.

MarkingSizeColourCheck cycle
Aisle edge100 mm wideyellow solidweekly
Walkway100 mm widegreen dashedweekly
No-store zone100 mm hatchingyellow and blackfortnightly
Press number200 mm highwhitequarterly

Repainting follows wear: a line at an aisle mouth loses about 30 percent within three months, and at 30 percent it is repainted as a full run, never patched, because a seam reads as a change of width. Injection floor layout ties that work to a service day, and puts speed signs at 2.2 m: 5 km/h in the hall, 3 km/h at corners.