Quick answer: A Medical mini centrifuge shockproof box keeps lid offset under 0.6 mm after a 5-200 Hz / 2 h sweep, using a 45 Shore A pad and a 9 mm lid press block.
Table of contents
- Medical mini centrifuge shockproof box pad hardness
- Lid press block thickness
- Lid offset across the sweep band
- Pad rebound under full load
- Hardness grading for medical batches
- FAQ
1. Medical mini centrifuge shockproof box pad hardness
Small centrifuge units react to broad-band vibration, and pad hardness plus press block thickness decides whether the shell keeps that excitation outside the cavity. A Medical mini centrifuge shockproof box measures 470 x 350 x 200 mm outside and 405 x 290 x 140 mm inside, with a 3.9 mm wall, so the floor leaves barely a dozen millimetres for damping. A 45 Shore A elastomer covers the floor and isolates the 5-200 Hz input by deflection. Too soft tracks the table; too hard passes high-frequency energy to the liner.
On the rig one shell takes three pad grades under a 7 kg mass, logging residual set and lid offset after each sweep. The reference is 45 Shore A, neighbours step 5 hardness units away, and their numbers only set a trend. Once the pad is fixed for a Medical mini centrifuge shockproof box, floor groove, block and gasket compression trace back to that grade.
| Hardness grade | Pad | Block | Set | Offset |
|---|---|---|---|---|
| Soft | 40 Shore A | 9 mm | 0.52 mm | 0.71 mm |
| Reference | 45 Shore A | 9 mm | 0.34 mm | 0.48 mm |
| Hard | 50 Shore A | 9 mm | 0.29 mm | 0.63 mm |
The reference lands at 0.34 mm inside the 0.4 mm limit; the other two drift outward on offset.
2. Lid press block thickness
With the lid closed, the press block pushes cavity-side movement back onto the sealing flange. The 9 mm block works against a 45 Shore A floor pad; too thin opens the lid mouth, too thick drives the gasket past 18% compression. On a Medical mini centrifuge shockproof box the block runs around the lid mouth, two 340 N latches flank the handle, and preload spreads over the flange.
One gasket at 18% compression is retested at 23 C / 50% RH, and flange rebound must survive 3800 open-close cycles. Lid ribs brace the block so a local dip cannot become a visible seam. The check records shell-side preload and flange gap only.
3. Lid offset across the sweep band
The 5-200 Hz / 2 h run is the only broad-band test here. The rig starts at 5 Hz, pauses each decade and logs offset at four lid corners; the line after the sweep is lid offset at or below 0.6 mm. A Medical mini centrifuge shockproof box absorbs low-frequency travel in the pad and locks the lid with block and flange at high frequency.
| Sweep band | Input | Lid offset | Pad response |
|---|---|---|---|
| 5-30 Hz | Table travel | 0.48 mm | Deflection |
| 30-100 Hz | Resonance | 0.55 mm | Hardness driven |
| 100-200 Hz | Transfer | 0.39 mm | Block driven |
The 30-100 Hz band reads highest, where lid and wall resonance overlap and the 45 Shore A pad flattens the peak. Offset is taken at four corners and the maximum, never the mean, is compared with 0.6 mm. Ten minutes after the sweep the corners are read again at 23 C / 50% RH.
4. Pad rebound under full load
A 7 kg load repeats the sweep, watching rebound rather than first-pass offset. Under full load a Medical mini centrifuge shockproof box keeps the floor pad compressed, and residual set after unloading must hold at 0.4 mm; weak rebound means the grade was too soft. The 23 C / 50% RH condition stays fixed.
Residual set is taken 30 min after unloading, apart from the instant value at sweep stop. One shell runs three loaded passes, and the three grades are gathered into one offset comparison; the reference rebounds most steadily while the soft grade nears 0.4 mm by the third pass. The 9 mm block and 18% gasket stay untouched across all three.
| Offset value | Empty | Loaded 1st | Loaded 3rd |
|---|---|---|---|
| Soft grade | 0.36 mm | 0.44 mm | 0.52 mm |
| Reference | 0.28 mm | 0.34 mm | 0.37 mm |
| Hard grade | 0.41 mm | 0.49 mm | 0.58 mm |
The 0.37 mm after three passes is the reference margin, still short of 0.4 mm. The hard grade starts with less set but lifts lid offset to 0.58 mm at high frequency.
5. Hardness grading for medical batches
Before batch release the grade is locked into one table. The hardness grade is fixed at the step just before residual set first reaches 0.4 mm, and softer pads stay as trend records only. A Medical mini centrifuge shockproof box is checked against the IP65 reference, and the flange gap must sit inside block preload after 3800 cycles.
If pad hardness drifts soft across a lot, lid offset rises before residual set does, and the rig tightens the grade one pass early. JUNZHIJIA shells are moulded by Ke Xin New Materials (Guangdong) Co., Ltd. to drawing, with pad, block and latch assembled at three stations.
Pad hardness, block thickness and sweep band are each simple alone; the difficulty is how they pull on one shell. Soften the pad a grade and the block needs thickness to restore preload. Thicken the block and gasket compression leans toward its 18% ceiling. Low- and high-frequency peaks sit at different points, so only a grade holding both works. The loaded retest confirms no permanent set after unloading. Open-close retest follows, and 3800 cycles without looseness close the grade out. The grading table for a Medical mini centrifuge shockproof box keeps one reference row.
Conclusion
A Medical mini centrifuge shockproof box keeps broad-band vibration out of the cavity by holding 45 Shore A pad, 9 mm block and 18% gasket compression on one grade. Lid offset at or below 0.6 mm and residual set at or below 0.4 mm after 5-200 Hz / 2 h are the two hard shell-side readings. Once the grade is locked, retests only confirm the trend has not drifted off the table.
Related Reading
- Anti-static precision instrument protective case
- Diagnostic device hard case with custom foam