Quick answer: Tool Case Trial Fit reads three numbers: a 0.05 mm feeler that will not enter the lid gap, 10–12 mm latch travel, and a 0.4 s handle return.
Table of contents
- How Tool Case Trial Fit Starts: Lid Gap
- Choosing a Feeler Gauge and Reading It
- Latch Travel: Engagement and Over-Centre
- Handle Spring-Back: Three Pulls
- What First-Off and Patrol Each Measure
- FAQ
1. How Tool Case Trial Fit Starts: Lid Gap
The bench is 1.2 m wide and held at 23 ± 2 C. A case rests on it 30 minutes before measuring, so the opening finishes springing back from moulding stress; a warm, freshly ejected case reads 0.1–0.2 mm tight.
Lid gap means the slit along the tongue edge once the lid is closed. It is five numbers, not one: each corner plus each long-side midpoint. A 0.05 mm blade blocked at all five passes; a 0.10 mm blade entering anywhere sends the tool back for adjustment.
The gap tracks mould tolerance. Under GB/T 14486 grade MT3, a 100–120 mm dimension carries ±0.58 mm, so a Tool Case Trial Fit that trusts the drawing nominal will pass parts that leak. Above 0.8 mm the gasket never seats.
Keep one signed sample case on the bench. Every tool, resin or shift change is compared against it on colour, gap and latch feel.
| Station | Gauge | Limit | Recorded |
|---|---|---|---|
| Lid gap | 0.02–1.00 mm feeler set | 0.05 mm blocked at five points | Five gap readings |
| Latch travel | 0–150 mm vernier | 10–12 mm | Left and right travel |
| Latch force | 0–50 N spring scale | About 12 kg | Peak pull |
| Handle return | 50 N weight and timer | Back within 0.4 s | Three return times |
2. Choosing a Feeler Gauge and Reading It
The usual shop gauge is a 17-blade set covering 0.02–1.00 mm with 100 mm blades. Steps run 0.01 mm from 0.02 to 0.10 mm and 0.05 mm from 0.10 to 1.00 mm, holding within 0.005–0.02 mm. A Tool Case Trial Fit needs the first six blades only.
A Tool Case Trial Fit reading is by drag, not by eye. A blade sliding in with slight resistance matches the gap; one dropping in freely means the gap is wider; one that will not start means it is narrower. Stacks top out at 0.15 mm, and past that a single blade is more honest.
Wipe blades and tongue before each reading. Oil or release agent makes the steel skate and the number comes out 0.02 mm small, enough to wave a bad case through. Never force a blade: the tool that bent it misreads every case behind.
| What the blade does | Call | Action |
|---|---|---|
| 0.05 mm blocked at all five points | Tight | Pass, latch feels firm |
| 0.05 mm enters, 0.10 mm blocked | Good | Record five readings |
| 0.10 mm enters, 0.30 mm blocked | Loose | Adjust mould, re-check |
| 0.30 mm or more enters | Out of limit | Stop line, inspect insert |
3. Latch Travel: Engagement and Over-Centre
Travel is the lever tip movement, from the hook touching its keeper to the lever bottoming out with a small click. The window is 10–12 mm. Under 10 mm the lever stops short and leaves a gap over 0.3 mm; past 13 mm too little spring is left after the over-centre point, and a case carried by the handle pops open. That 2 mm is why a Tool Case Trial Fit gives travel its own station.
Use the depth rod of a vernier against the keeper edge. Measure both latches and hold the pair within 1 mm; a wider spread tilts the lid, and it is the item most often skipped.
Latch force comes from a 0–50 N spring scale hooked 25 mm from the pivot, pulled at 20 mm/s. About 12 kg is near 118 N, the band that holds the gasket at roughly 25% compression. Below 8 kg the seal is unloaded; above 16 kg a thumb cannot close the case.
| Item | Gauge | Pass band | Symptom when out |
|---|---|---|---|
| Travel | Vernier depth rod | 10–12 mm | Stops short or pops |
| Left-right spread | Vernier | 1 mm or less | Lid lifts on one side |
| Latch force | 0–50 N spring scale | 10–14 kg | Gasket loose or stiff |
| Over-centre | Hand and ear | A click, no rebound | Silent, opens on release |
4. Handle Spring-Back: Three Pulls
Spring-back is how long the handle takes to return once the load comes off. Hang 50 N at the handle midpoint, hold 60 s, release without warning, film at 240 frames per second: a Tool Case Trial Fit wants the return inside 0.4 s with under 1 mm of droop.
Run three pulls, 30 s apart. A handle returning in 0.35 s then 0.6 s has a boss that is creeping, and the Tool Case Trial Fit should set that case aside and look for whitening at the boss root. Whitening marks where the stress sits, and two loaded lifts will start a crack.
Temperature rewrites the timeline. A handle that returns in 0.4 s at 23 C needs 0.1–0.2 s longer at -10 C, and the first feel a winter customer gets is a stiff handle. Cold-region orders need a limit taken from the cold re-test.
5. What First-Off and Patrol Each Measure
First-off measures all five items: gap at five points, travel, latch force, handle return and appearance. The case is then kept as the signed sample and photographed with the feeler still in the tongue, the only evidence when a batch is disputed. A Tool Case Trial Fit without a signed first-off has no baseline for the run.
Patrol takes 5 cases every 2 hours and measures gap and travel; force, return and appearance are re-checked once a shift. Sampling follows AQL 2.5: one failure in 5 triggers 10 more, two failures in 20 send the lot back. Write that rule on the back of the sheet.
The Tool Case Trial Fit record sheet runs by station, not by item. One case is one row, five station readings across, inspector and time at the end. Read sideways, a drifting machine shift shows as a block of numbers. Leave a box for the mould number at the bottom right; if it does not match, the page is void.
| Stage | Frequency | Sample | Measured |
|---|---|---|---|
| First-off | Once per mould per shift | 1 case | All five items |
| Patrol | Every 2 hours | 5 cases | Gap, travel |
| End of shift | Once per shift | 3 cases | Force, return, look |
| Mould change | Every change | 1 case | All five items |
Conclusion
This article covers only the specifications and design meaning on the container (case) side, and does not deal with any handling, loading or use of the contents.
Related Reading
- How assembly standards reach the bench
- Sampling an incoming batch
- Reading AQL 2.5
- Choosing and aligning latches
- How hinge life is tested
Related Products
- 8 Series — Gun Cases; Military Equipment Cases; Camera Equipment Cases; Drone Cases; Watch Cases; Knife Cases; First Aid Cases; Electronics Equipment Cases
- WL8-2812 PP Gun Case — model WL8-2812
- All protective cases and toolboxes: 7 series, 158 models