Quick answer: The Ultrasonic thickness gauge portable protective box gives two φ32 mm wells, a couplant cell and a cable bay their own walls at 1.6 kg.

Table of contents

  • Layout Zones in the Ultrasonic Thickness Gauge Portable Protective Box
  • Damping the Probe Cavities on Their Own
  • Keeping the Couplant Compartment Leak-Tight
  • Cable Coil Radius and the Exit Port
  • Cavity Values the Inspection Crew Works To
  • FAQ

1. Layout Zones in the Ultrasonic Thickness Gauge Portable Protective Box

A probe, a couplant bottle and a cable each need a patch of their own, with a boundary a hand can find without searching.

The Ultrasonic thickness gauge portable protective box runs 380×290×145 mm outside and 335×245×105 mm inside, behind a 3.8 mm wall. What remains after the wall and liner is the space the compartments share.

Compartments are laid out in reverse packing order. The couplant cell claims a 70×70×90 mm column, the two φ32 mm wells sit along the long edge, and the remaining strip becomes the cable bay. The cell reaches the floor so the bottle stands upright, with 5 mm of foam beneath it for the moment the case tips.

Cavity classSide clearancePull forceTypical fit
Tight class0.5 mm18 NFixed bench, probe rarely removed
Standard class1.0 mm12 NDaily inspection rounds
Loose class2.0 mm6 NSeveral probes rotated

Classes differ in clearance, not bore: every well is cut at φ32 mm, and sleeve thickness sets the rest.

2. Damping the Probe Cavities on Their Own

The Ultrasonic thickness gauge portable protective box carries two wells at φ32 mm, offset rather than in line. Each is wrapped in 2 mm of EVA, with 8 mm of solid material between them, so a hit on one does not set the other rocking.

Ultrasonic thickness gauge portable protective box showroom shelving with branded blue and black cases above olive, tan and orange models.
Ultrasonic thickness gauge portable protective box showroom shelving with branded blue and black cases above olive, tan and orange models.

The foam sits at 60 to 90 kg/m³, Shore C 25 to 40, the usual band for precision liners. Below 60 kg/m³ the cut walls fuzz and pill after a few dozen insertions; above 90 kg/m³ there is too little compression and the probe rides on a hard seat.

Each well is 6 mm deeper than the probe boot, so fingers grip the boot, not the cable. A common crystal is 10 mm across and the boot 26 to 28 mm outside, leaving 2 mm per side in a φ32 mm bore: easy in, not free to rattle.

The 8 mm divider gives each probe its own wall, so a side impact crosses it before reaching a cavity.

3. Keeping the Couplant Compartment Leak-Tight

On the Ultrasonic thickness gauge portable protective box the cell measures 70×70×90 mm, sized around a 75 ml squeeze bottle with 5 mm under the base and 10 mm above the shoulder. A 3 mm lip at the mouth catches liquid first when the bottle lies down.

Three details keep it dry. The floor is a shallow tray with an 8 mm rim. The walls are moulded in one shot with the case floor, leaving no joint to trap liquid. A 4 mm absorbent pad sits at the mouth and is replaced once saturated.

PP shrinks 1.2% to 1.8% while ABS stays at 0.4% to 0.7%. This layout has many compartments, so the low-shrink compound keeps a 70 mm mouth within 0.5 mm; a high-shrink resin would force a wider gap and let the bottle knock the wall on every tip.

Ultrasonic thickness gauge portable protective box final assembly line, stacked black cases beside wooden benches and three operators shrink-wrapping finished units.
Ultrasonic thickness gauge portable protective box final assembly line, stacked black cases beside wooden benches and three operators shrink-wrapping finished units.

4. Cable Coil Radius and the Exit Port

The Ultrasonic thickness gauge portable protective box keeps its cable bay along the lid side, 60 mm wide, so a wound coil drops in without force. The exit sits above the parting line as a 35×20 mm opening with 3 mm rounded edges, so the jacket is not scraped as the cable moves.

On the Ultrasonic thickness gauge portable protective box the cable is 1.2 m. At a 45 mm radius one turn measures about 283 mm, four turns reach 1.13 m, and the last 70 mm hangs from port to wrist. Below 45 mm the bending stress climbs and the shield fails at the port long before the case does.

Coil turnsCoil radiusUnrolled lengthTail at port
3 turns45 mm0.85 m350 mm
4 turns45 mm1.13 m70 mm
5 turns45 mm1.41 mNone

The port stays clear of the handle, so cable drops straight down. Five turns unroll to 1.41 m, some 210 mm beyond the cable, and that surplus folds back below 45 mm as the fatigue point.

5. Cavity Values the Inspection Crew Works To

The Ultrasonic thickness gauge portable protective box sets cavity values at the tightest class that still shows no leak after thirty minutes of tipping; looser classes carry dry accessories only.

The tip test fills the bottle to eighty percent, closes and latches the case, leans it 45 degrees forward, back, left and right, and holds 30 min at each attitude before opening to look for a trace.

Leak readingTip durationBottle attitudeVerdict
0 g30 minUprightPass
0.4 g30 minOn its sideRetest once
2.1 g30 minInvertedFail

Open and close is rated at 3800 cycles on a metal pin in a self-lubricating bush, and two draw latches pull 280 N each to hold the gasket at thirty percent compression. The shell is checked against the IP66 reference: a 12.5 mm nozzle at 100 L/min from 2.5 to 3 m over six faces.

At 1.6 kg the Ultrasonic thickness gauge portable protective box stays a one-hand carry when loaded, a figure from a uniform 3.8 mm wall plus local ribs, not a thicker shell.

Conclusion

Zoning an Ultrasonic thickness gauge portable protective box means drawing three boundaries inside 335×245×105 mm: a 0.5 mm clearance per well, a shallow tray under the cell, and four cable turns at 45 mm. Fix those and thirty minutes of tipping leaves a dry floor. At 1.6 kg and 3800 cycles, the case side of the design is closed.