Quick answer: Valve and Instrument Protective Case keeps Ra 3.2 µm flange faces off the load path: 3–12 kg bodies rest on 4–6 points, mixed loads under 8 items.

Table of contents

  • The flange sealing face must not carry load
  • How valve body weight is spread over support points
  • Clearance for gauge heads and threaded ports
  • Separation and layering in mixed loads
  • Unpacking order and repacking
  • FAQ

1. The flange sealing face must not carry load

A Valve and Instrument Protective Case splits its cavity into two zones, one for valves and one for gauges, because the two object types fear different things. A valve is heavy and carries a finish-turned flange face. A gauge is light and carries a glass dial plus a threaded port. The heavy part worries about being under-supported; the light part worries about being pressed on.

That Ra 3.2 µm face is what two flanges squeeze together, and flatness is what lets a gasket seal. Use it as a cavity floor and stacked weight travels down the gasket line. The dent is too shallow to see and deep enough to cost a re-torque on refitting: roughly 0.1 mm already defeats a soft gasket, and foam rebound will not push metal back.

Aim the face at a side wall or let it hang, so support lands on the outer rim behind the flange. A Valve and Instrument Protective Case keeps bearing points on thick sections, because metal on foam concentrates pressure as contact area shrinks:

Flange orientationCavity floorBearing locationValve body range
Face upFloor cut away, face floatingOuter rim behind flange3–6 kg band
Face sidewaysFoam bears on the sideCylindrical body section6–9 kg band
Face downCorner posts hold the rimOuter rim and stem shroud9–12 kg band

2. How valve body weight is spread over support points

A 3–12 kg body cannot ride on one foam block. The Valve and Instrument Protective Case floor takes load through 4–6 support points around the mid-section, so force runs from the body into the floor instead of into the flanges. Drop one point and the rest each carry more; a 2.0–3.5 mm wall then bows at mid-height under long stacking.

Valve and Instrument Protective Case opened, black foam in the lid cut to stepped pockets, base split into compartments
Valve and Instrument Protective Case opened, black foam in the lid cut to stepped pockets, base split into compartments

Point count follows three weight bands rather than one blanket figure. Latch holding force of 200–400 N governs lid closure only, never floor load.

Body weightSupport pointsLoad per pointFloor treatment
3–6 kg40.75–1.5 kgCavity cut in one foam block
6–9 kg51.2–1.8 kgCavity plus base pad
9–12 kg61.5–2.0 kgCavity plus backing plate

The plate spreads six point loads into an area so foam is not punched through. The stem needs its own thought: slender and protruding, it bends first in a drop. Its shroud pocket runs slightly loose so the stem shifts sideways; clamping it hard only moves the bend to the packing gland. Valves with handwheels travel handwheel-up, the wheel floating in a lid recess.

3. Clearance for gauge heads and threaded ports

The dial is what gets overlooked. Dials come in 60 mm and 100 mm sizes, the window is glass or acrylic, and the retaining lip around it is thin. This Valve and Instrument Protective Case cuts a lid pocket that stands 1–2 mm per side clear of the dial outline, so closed foam touches the case rim only and never the window.

The port is the second trouble spot. An M20×1.5 thread end must stay flat; foam pressed onto it burrs the chamfer and sealing tape will not wrap cleanly. Carry the pocket past the port face and aim the port at a side wall, so a sideways knock pushes it sideways instead of driving it axially into foam.

Dials facing upward need one extra step. Their weight sits between the case and the lid foam, so that layer must not be cut through; a cut-through leaves the dial hanging. When a dial will not fit its pocket, the honest answer is a different case size, since pocket depth follows dial height and not dial diameter.

4. Separation and layering in mixed loads

Valves and gauges can share a case, but the count needs a ceiling. This Valve and Instrument Protective Case layers three levels with no more than 8 items inside: gauges on top, small valves in the middle, large valves at the bottom. Past 8, divider sheets thicken, clamp force stops reaching every item, and the top item loosens first.

Valve and Instrument Protective Case long black form, chrome draw latches at both ends, moulded centre handle aligned
Valve and Instrument Protective Case long black form, chrome draw latches at both ends, moulded centre handle aligned

Separation is more than a sheet of sponge. A rigid divider goes between gauge and valve so the dial face and the flange face never press on each other; a Valve and Instrument Protective Case gives two valves side by side a height-limited divider, low enough for fingers and high enough that the pair cannot knock together in transit.

LevelContentsSeparationItem ceiling
TopGaugesEgg-crate lid foam plus divider3 items
MiddleSmall valvesHeight-limited dividers3 items
BottomLarge valvesIndividual pockets plus plate2 items

Heavy goes low and light goes high, yet a dial-up gauge should not sit at the outer edge of the top level, where fingers reach first; dial items belong against the handle side, so the first thing seen is whether the witness mark has moved.

5. Unpacking order and repacking

Unpacking runs opposite to packing, and the reason is the flange face rather than ceremony. Open a Valve and Instrument Protective Case and top gauges come out first, then the middle level, then the bottom valves, each lifted vertically. A tilted pull drags the flange rim along the foam wall, and the debris it raises settles on the sealing face.

Repacking depends on numbers: every pocket carries a position number pressed into the foam, and each item returns to its own pocket, since each pocket was cut to one body shape. Mixed-load verdict: any indentation on a flange sealing face, or more than 1 mm of axial movement on a gauge head, means the pocket layout of that case is unusable.

Shell sealing is separate. IP67 at 1 m / 30 min asks whether water enters; a flange face worries about mechanical marks. Repairs differ: water means gasket and latches, marks mean pockets and supports. Close the lid with latches drawn diagonally, those beside the handle last.

This article covers only the specification and design meaning on the case side.