Quick answer: Most Projectile Pallet acceptance decisions need no outside lab: four of the six checks close on the receiving dock the same day, provided gauge and limit are pinned down first.

Table of contents

  • Six Checks on One Sheet
  • Gauges and Measuring Points
  • Appearance and Structure: Three Defect Classes
  • Performance Sampling: Stack, Drop and Cold
  • Disposition of Nonconforming Units
  • FAQ

1. Six Checks on One Sheet

An inspection sheet fails because every item sits in one flat list, so the receiver cannot tell what must close today. On a Projectile Pallet the six checks split by origin of the result: documents, gauges, bench tests. The first two close on the dock; bench tests run at first article and batch re-verification only.

Documents decide whether paperwork matches goods. The material certificate must name grade and lot, and the first-article report must carry measured values for the first, middle and last parts; three identical numbers usually mean nothing was measured.

CheckGauge or recordMethodAccept limit
Dimensional chainClass II tape, caliper3 points per side, diagonalsDiagonal gap 3 mm max
Wall thicknessBall-anvil micrometer3 points per long side3.0 mm, plus or minus 0.25
Appearance500 lux or daylightOne pass at 600 mmNo through cracks
StackWeights or ballast1.5 times load, 24 hoursDeflection 2.5 mm max
Salt sprayNeutral cabinet5 percent salt, 35 C, 48 hoursScribe creep 2 mm max
TraceabilityMark and resin ledgerTrace three unitsAll resolve to a mould

The second column is the one that gets skipped; swap the gauge and the verdict moves by half a tolerance band.

2. Gauges and Measuring Points

A reading you cannot repeat turns inspection into opinion.

Projectile Pallet: olive green case open on a steel bench, egg-crate foam in the lid, six cut compartments below, folding handle
Projectile Pallet: olive green case open on a steel bench, egg-crate foam in the lid, six cut compartments below, folding handle

Measure where the load goes, not where the surface is easy to reach. Wall thickness reads at three points per long side, 50 mm in from either end, plus two on the base ribs. Take length at the rim plane, because a jaw pushed into the corner radius slides inward.

Five tools cover the dock:

  • Class II steel tape, 3 m, for length and diagonals
  • Vernier caliper, 0.02 mm, for rim and latch seats
  • Ball-anvil micrometer for curved walls
  • Feeler gauges, 0.02 to 1.0 mm, for the lid gap
  • A colour chip for batch shade

Log three values per Projectile Pallet: point, reading, verdict. Drop one and a re-check cannot tell whether part or inspector changed. Keep a sealed first-article sample stamped with the mould number as the reference in any dispute.

3. Appearance and Structure: Three Defect Classes

Appearance calls break down on two phrases: close enough, and it will not affect use. Three classes end that.

ClassTypical signRuleAQL
CriticalThrough crack, broken latch seatOne unit rejects the batch0
MajorUnfused area, void over 3 mmReject past the acceptance number1.0
MinorShade drift, flow line, light scuffRework or concession2.5

The classes differ by an order of magnitude in cost. A critical defect stops the line and sends someone to the mould; a major one implicates a single cavity; a minor one is settled in-house.

The structural item worth separating from appearance is lid-to-body fit. Run a 0.2 mm feeler around the perimeter: where it enters, the gasket is under-compressed; where it will not enter but light shows through, the latch will fatigue first. Both distort the salt spray result.

4. Performance Sampling: Stack, Drop and Cold

Bench tests run twice: first article from a new mould, and three units per batch. Order matters: stack, drop, cold.

Projectile Pallet: olive green case on bare concrete, four latches on the long side, a round valve cap at right
Projectile Pallet: olive green case on bare concrete, four latches on the long side, a round valve cap at right

Stack at 1.5 times the rated load for 24 hours. A Projectile Pallet rated at 45 kg per layer is pressed at 67.5 kg, then left two hours before the base centre is measured. Two and a half millimetres or less passes; measuring straight away counts elastic recovery as permanent set.

Drop from 1.2 m, once on each of six faces and once on three edges. Two things are read afterwards: whether the latches close, and whether the joint has shifted.

Cold comes last because it changes toughness. Four hours at minus 25 C, then a drop within 30 seconds, since the material warms quickly and a room-temperature drop measures something else.

5. Disposition of Nonconforming Units

A failed verdict is only the start; disposition decides the route: rework, screening, concession.

Rework covers repairable items such as shade, offset labels and flash. The re-check must repeat the original scope rather than the fixed item, because a second oven pass often introduces fresh distortion.

Screening suits uneven distribution. When wall thickness falls below the lower limit, full inspection separates the good units at a cost in labour. Screened units get a new batch number; mixing them into the original lot breaks the trace.

Concession needs a written deviation permit naming the item, quantity, permitted use and responsible party. Concessioned Projectile Pallet units are downgraded and kept off the main assembly line.

Conclusion

Acceptance of a Projectile Pallet is measured not by the length of the sheet but by whether all six checks end in a number. Documents cover origin, gauges the dock, bench tests the batch. Settle the measuring points before the first delivery, and every later Projectile Pallet batch is argued with data.

This article discusses only the container (case body) side of specifications and design intent, and does not cover any handling, loading or use of the contents.