Quick answer: A prop charge container passes on three independent sets of evidence, not a caliper reading. Dimensions, a 60 second hold at minus 30 kPa, and drops from 0.9 m and 1.5 m each stand alone.

Table of contents

  • Wall Thickness Is Not a Verdict
  • Appearance and Dimensions
  • Pressure Decay and Leak Location
  • Drop and Stack Tests on Site
  • Salt Spray and Thermal Cycling
  • Three Disposition Lines
  • FAQ

1. Wall Thickness Is Not a Verdict

The argument never changes: the caliper reads 3.5 mm, so why hold the batch. Thickness is a design input, not an acceptance result, and it says nothing about a flat sealing face.

A prop charge container passes on three independent groups of evidence: dimensions prove it closes, the seal proves it holds, the structure proves it survives a fall.

GroupMethodCriterion
DimensionsCMM or go/no-go gaugeCavity 158 mm, tolerance 0.5 mm, gap 0.8 mm max
SealDifferential, minus 30 kPa, 60 sDecay 0.8 kPa or less
StructureDrops 0.9 m and 1.5 m, 5 high 72 hNo through crack, set 3 mm max

Sampling gets fixed first: 5 percent of a batch, floor of three cases, seal on every unit, drops at 2 per thousand.

2. Appearance and Dimensions

Three places never show on a thickness reading: parting line mismatch, gate marks, whitening near inserts. All sit near the sealing face.

Prop Charge Container: olive case open on a wooden table, egg-crate foam in the lid, a divided tray, a red valve knob, tools at right
Prop Charge Container: olive case open on a wooden table, egg-crate foam in the lid, a divided tray, a red valve knob, tools at right
  • Cavity 158 by 492 mm on a go/no-go gauge
  • Lid gap by feeler gauge at eight points, 0.8 mm max
  • Latch pull 350 N for 10 seconds, fitted at 8 N m
  • Seal groove 4 mm plus or minus 0.1 mm, no flash
  • Sealing face flat within 0.4 mm over 300 mm
  • Wall by ultrasonic gauge, five points per face, nothing under 3.3 mm

Flatness is the one that gets skipped. Four tenths sounds generous until you remember the gasket compresses 1.2 mm, so a 0.6 mm hollow eats half of it.

3. Pressure Decay and Leak Location

Most decay disputes come from temperature, not equipment.

A case needs four hours in the test room. Move a prop charge container from a 35 C floor into a 20 C room and the trapped air contracts, so the gauge climbs and a leaking unit looks fine; move one from 5 C into 20 C and a good unit fails.

DriftCorrectionShare of the 0.8 kPa limit
2 C0.04 kPa5 percent
5 C0.10 kPa12 percent
10 C0.20 kPa25 percent

When a unit fails, locating the leak beats scrapping it. Soap the groove for bubbles, pull the latches, check for a collapsed base, then suspect the body. Most trace to under-torqued latches or a split gasket corner.

4. Drop and Stack Tests on Site

Drops run at two levels: a single case and a pallet fail differently.

Prop Charge Container: khaki case in a grey tray on a steel counter, foam holding circuit boards, a handheld reader, a round valve
Prop Charge Container: khaki case in a grey tray on a steel counter, foam holding circuit boards, a handheld reader, a round valve

A single case falls 0.9 m onto concrete on corner, edge and face, checked for through cracks and popped latches. A pallet falls 1.5 m, where the contact zone takes twice that stress. Concrete barely rebounds, so the case absorbs the energy.

Stack five high for 72 hours at 40 C, months of creep in three days: the bottom lid sets 3 mm or less, recovering to 1 mm in 24 hours. Stack first, then drop.

5. Salt Spray and Thermal Cycling

Metal ages faster than polymer, so salt spray targets latches, hinges, valves.

Neutral salt spray for 480 hours, scribe creep under 2 mm per side, latches latching after 500 cycles, colour difference of 3 or less. Thermal cycling runs 4 hours at minus 40 C and 4 hours at plus 71 C for seven cycles. UV of 300 hours leaves no crazing.

Samples stay separate even in one order: latches and hinges for salt spray, a whole case for thermal cycling, plaques for UV.

6. Three Disposition Lines

Disposition belongs in the spec, not on the floor.

DefectLineBoundary
Gap 0.8 to 1.2 mm, decay 0.8 to 1.5 kPaReworkGasket or latch fix, one rework only
Wall 3.0 to 3.3 mm, no crackingDowngradeNon-pressure duty, marked, kept apart
Through crack, decay above 1.5 kPaScrapDestroyed on site, no return to stock

The lines do not cross: a prop charge container failing its single rework goes to downgrade or scrap, stored apart.

Conclusion

Acceptance is hard because the three groups stay independent: for a prop charge container, thickness, seal and structure each cover their own ground. Fix 158 mm, 0.8 kPa, 0.9 m, 1.5 m and 480 hours, and acceptance stops collapsing into a caliper reading.