Quick answer: A 700×1000×600 mm CMM travelled 380 km for annual calibration, and the testing equipment protective case was the easy part. Pad compression, bolt order and second lifts decided the result. What follows: 25 mm pads, 6 N·m diagonal torque, a 0.02 mm/m level check, arrival re-verification.

Table of contents

  • What this testing equipment protective case had to carry
  • Loading the CMM: pad thickness and bolt order
  • Spectrometer and accessory bays
  • Level and pad compression checked on site
  • Counting the second lifts
  • Paperwork inside the case and re-verification on arrival
  • FAQ

1. What this testing equipment protective case had to carry

A tier-two automotive supplier in Suzhou sends a four-year-old CMM 380 km for annual calibration. Two earlier trips went in a timber crate, and the Z-axis error arrived at 4.7 μm instead of 2.1 μm — inside tolerance, but enough for an auditor to ask why.

Three dimensions came first: door clearance 1.6 m, tail-lift height 0.9 m, lifting-point spacing 1.2 m. They decide whether the machine travels assembled.

The load is four items.

ItemNet weightEnvelope mmSensitive point
CMM main unit620 kg1180×1420×2050guideways and glass scales
Control cabinet45 kg600×800×1200board connectors
Portable spectrometer18 kg480×380×220optical window
Probe and master ball3.2 kg210×160×90ruby tip

The envelope of the testing equipment protective case is set by the longest item, the interior split by the most sensitive one.

2. Loading the CMM: pad thickness and bolt order

A cast-iron base cannot sit straight on the case floor. Without continuous bearing, four uneven contacts twist the column.

Testing equipment protective case: a long flat brown shell lying closed on a cabin porch deck, both latches shut, scuffed lid, firewood and boots behind
Testing equipment protective case: a long flat brown shell lying closed on a cabin porch deck, both latches shut, scuffed lid, firewood and boots behind

Padding is 25 mm closed-cell EPDM, cut into 120 mm × 100 mm blocks at six points, never one sheet. A sheet leaves the base spanning air and turns the pad into a drum skin.

Thicker is not better; past 30 mm the machine rocks.

Torque goes diagonally: two diagonal points at 6 N·m, the centre pair at 2 N·m preload, the last two re-tightened after two hours because the foam creeps 1 mm. Four hours on, two points had fallen to 5.2 N·m.

One pass never holds.

3. Spectrometer and accessory bays

The main unit takes seven tenths of the interior; the rest of the testing equipment protective case goes to the spectrometer and accessories, listed rather than tabulated because each is counted as it goes in.

  • Portable spark spectrometer, 18 kg, own bay with 15 mm clearance
  • Electrode stand and spark stand on the shelf above that bay
  • Four reference blocks, each in a slot 12 mm deep
  • Two argon hoses coiled to 200 mm and tied to the wall
  • Mains and signal leads in one bundle, 50 mm slack at each end
  • Manual and certificate copy in a dry bag on the top layer
  • Two spare probes, ruby tips up, in foam pillars

Bays exist so counting is possible. Read the list aloud, then close the lid; a missing part surfaces on arrival and costs two days.

4. Level and pad compression checked on site

Packing is not the finish line. Before the lid closes, level is read again at four points on the worktable.

Testing equipment protective case: olive green shell open on a cabin deck, orange dividers making four bays, flat lid liner, two latches and side knob
Testing equipment protective case: olive green shell open on a cabin deck, orange dividers making four bays, flat lid liner, two latches and side knob

The spread must stay inside 0.02 mm/m. Tolerance is 2.5 μm, and every 0.01 mm/m adds about 0.4 μm of cosine error over a 1 m stroke, leaving no margin for road vibration.

Compression is read at the same time. A 25 mm pad under 103 kg per point should compress under 3 mm.

Order matters too. Empty case first, machine in second, two hours after torque third. The readings went on one sheet: 0.008, 0.014 and 0.011 mm/m. If the third is worse than the second, look at the bolt order, not the shell.

5. Counting the second lifts

Count the lifts: four on this route — pallet truck, tail lift, tail lift, forklift — and two involved a turn.

Straight runs peaked at 1.8 g; a turning lift peaked at 3.4 g, because one side leaves the ground and load runs through the pad edge.

Avoid the turn.

Tilt indicators stayed clear; a 20 mm corner scuff showed a grazed van pillar.

6. Paperwork inside the case and re-verification on arrival

Paper travels too inside the testing equipment protective case: certificate copy, packing list, torque record and level readings, in a dry bag.

Three checks on arrival.

CheckCriterionRecorded by
Repeatabilitywithin 1.0 μm of factory valuelaser interferometer, three points
Indication errorwithin 2.5 μm over full rangefive-step gauge block comparison
Probe trigger forcewithin 0.02 N in any directionforce gauge, probe by probe

Repeatability moves first. It follows shell stiffness, but also pad shift: 5 mm of shift can cost 0.6 μm.

Conclusion

Most of a calibration trip is settled before the lid closes. Counting the load, cutting the pads, torquing diagonally and re-reading the level keep numbers stable over 380 km. Holding those conditions is the job of a testing equipment protective case.

This article discusses only the container (case body) side of specifications and design intent, and does not cover any handling, loading or use of the contents.